EXTERIOR LAMPS — Turn Signal and Hazard Warning Lamps / Wiring Diagram (Cont'd) — R.H.D. Model (Base K11)
EL-74wiring diagramBase K11 EXTERIOR LAMPS — turn signal + hazard wiring, RHD (UEL136). Same as LHD (EL-73): flasher unit → turn switch (R/N/L) + hazard switch → front/side/rear turn lamps + meter. RH=G/Y, LH=G/B. SMJ E55/M59 via A6 (vs F8 LHD). Variant M/T vs N·CVT (routing only). [Re-extracted: original write was interrupted.]
Turn Signal and Hazard Warning Lamps / Wiring Diagram (Cont'd)
R.H.D. Model
Turn signal + hazard wiring — RHD (UEL136)
Components (14)
BatteryFuse Block (10A)Ignition Switch ON or STARTCombination Flasher UnitHazard Switch (OFF/ON, terminals 1-8)Turn Signal Switch (R/N/L, in combination switch)S.M.J. (refer to Foldout page) — E55/M59 via A6Front Turn Signal Lamp R.H.Front Turn Signal Lamp L.H.Side Turn Signal Lamp R.H.Side Turn Signal Lamp L.H.Rear Combination Lamp R.H. (turn)Rear Combination Lamp L.H. (turn)Combination Meter (turn indicators RH/LH)
Connections (10)
Fuse Block (10A)
Fuse Block (10A)Combination Flasher UnitGreen
Combination Flasher Unit
Combination Flasher UnitHazard Switch (OFF/ON, terminals 1-8)Green/Red
Combination Flasher UnitTurn Signal Switch (R/N/L, in combination switch)Light Green/Black
Turn Signal Switch (R/N/L, in combination switch)
Turn Signal Switch (R/N/L, in combination switch)Front Turn Signal Lamp R.H.Green/Yellow (RH turn)
Turn Signal Switch (R/N/L, in combination switch)Side Turn Signal Lamp R.H.Green/Yellow (RH)
Turn Signal Switch (R/N/L, in combination switch)Rear Combination Lamp R.H. (turn)Green/Yellow (RH)
Turn Signal Switch (R/N/L, in combination switch)Front Turn Signal Lamp L.H.Green/Black (LH turn)
Turn Signal Switch (R/N/L, in combination switch)Side Turn Signal Lamp L.H.Green/Black (LH)
Turn Signal Switch (R/N/L, in combination switch)Rear Combination Lamp L.H. (turn)Green/Black (LH)
Turn Signal Switch (R/N/L, in combination switch)Combination Meter (turn indicators RH/LH)Green/Yellow + Green/Black (indicators)
NOTE
RHD version of the turn signal + hazard wiring (cf EL-73 LHD). Identical circuit — combination flasher unit drives the turn circuit (turn switch R/N/L) and the hazard circuit (hazard switch). RH=G/Y, LH=G/B to front/side/rear turn lamps + meter indicators. Only the SMJ routing differs (A6 vs F8 on LHD). Variant legend: M/T = manual transaxle, N·CVT = N·CVT models (harness/SMJ routing only).
See also
S.M.J. Foldout page · Power Supply Routing