POWER SUPPLY PROTECTION — Wiring Diagram (Cont'd) — R.H.D. Model With Super Multiple Junction (Base K11)
EL-14wiring diagramBase K11 RHD power supply (With S.M.J. variant). Routes through S.M.J. consolidation block. Pairs with EL-12 (without S.M.J.). DIM-DIP for headlamps (UK).
Wiring Diagram (Cont'd)
R.H.D. Model — With Super Multiple Junction
NOTE
Base K11 RHD power-supply routing for the 'With Super Multiple Junction' variant — circuits route through the S.M.J. consolidation block (reference to foldout page EL-1048) instead of direct connector-to-connector wiring (EL-12).
Same distribution tree and component complement as EL-12: battery → fusible links → fuse block/S.M.J. → system branches. RHD uses DIM-DIP LAMP UNIT for headlamps (UK).
Variant tags M (M/T), C (N·CVT).
EL-12 (without S.M.J.) and EL-14 (with S.M.J.) document the two RHD wiring-loom variants. The S.M.J. version consolidates many harness joints into a single multi-terminal junction block — easier production, but means an S.M.J. fault affects many circuits at once.