Battery - Battery Test and Charging Chart (Cont'd) - C: Quick Charge, SDS
EL-22flowchartBattery Test and Charging Chart (Cont'd) - C: QUICK CHARGE
C: Quick charge
Probable Cause
Corrective Action
Determine initial charging current setting and charging time from specific gravity, referring to Fig. 6.
Charge battery.
Charge battery.
Go to 'CAPACITY TEST'.
Cause
Determine initial charging current setting and charging time from specific gravity, referring to Fig. 6.
Fix
Charge battery.
Cause
Charge battery.
Fix
Go to 'CAPACITY TEST'.
Fig. 6 - Initial Charging Current Setting and Charging Time (Quick charge)
1.100 - 1.130
28B19R(L) / 34B19R(L) - 10A2.5 hours
46B24R(L) / 55B24R(L) / 50D23R(L) - 15A2.5 hours
55D23R(L) / 65D26R(L) / 80D26R(L) - 20A2.5 hours
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L) - 30A2.5 hours
130E41R(L) - 40A2.5 hours
1.130 - 1.160
28B19R(L) / 34B19R(L) - 10A2.0 hours
46B24R(L) / 55B24R(L) / 50D23R(L) - 15A2.0 hours
55D23R(L) / 65D26R(L) / 80D26R(L) - 20A2.0 hours
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L) - 30A2.0 hours
130E41R(L) - 40A2.0 hours
1.160 - 1.190
28B19R(L) / 34B19R(L) - 10A1.5 hours
46B24R(L) / 55B24R(L) / 50D23R(L) - 15A1.5 hours
55D23R(L) / 65D26R(L) / 80D26R(L) - 20A1.5 hours
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L) - 30A1.5 hours
130E41R(L) - 40A1.5 hours
1.190 - 1.220
28B19R(L) / 34B19R(L) - 10A1.0 hours
46B24R(L) / 55B24R(L) / 50D23R(L) - 15A1.0 hours
55D23R(L) / 65D26R(L) / 80D26R(L) - 20A1.0 hours
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L) - 30A1.0 hours
130E41R(L) - 40A1.0 hours
Above 1.220
28B19R(L) / 34B19R(L) - 10A0.75 hours (45 min.)
46B24R(L) / 55B24R(L) / 50D23R(L) - 15A0.75 hours (45 min.)
55D23R(L) / 65D26R(L) / 80D26R(L) - 20A0.75 hours (45 min.)
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L) - 30A0.75 hours (45 min.)
130E41R(L) - 40A0.75 hours (45 min.)
NOTE
Check battery type and determine the specified current using the table shown above. After starting charging, adjustment of charging current is not necessary.
CAUTION
a. Do not use standard charge method on a battery whose specific gravity is less than 1.100.
b. Set charging current to value specified in Fig. 6. If charger is not capable of producing specified current value, set its charging current as close to that value as possible.
c. Keep battery away from open flame while it is being charged.
d. When connecting charger, connect leads first, then turn on charger. Do not turn on charger first, as this may cause a spark.
e. Be careful of a rise in battery temperature because a large current flow is required during quick-charge operation. If battery temperature rises above 60°C (140°F), stop charging. Never charge battery when its temperature is above 60°C (140°F).
f. Do not exceed the charging time specified in Fig. 6, because charging battery over the charging time can cause deterioration of the battery.
Service Data and Specifications (S.D.S.)
| Specification | Value |
|---|---|
| Battery type | 46B24R (L) |
| Capacity V-AH | 12 - 36 |
Battery type
46B24R (L)
Capacity V-AH
12 - 36
CAUTION
a. If it becomes necessary to start the engine with a booster battery and jumper cables, use a 12-volt booster battery.
b. After connecting battery cables, ensure that they are tightly clamped to battery terminals for good contact.