METER AND GAUGES — Failure Chart for "Error code"
EL-7041spec tableError-code reset paths: disconnect battery or just wait 20s for the self-diag mode to timeout — there's no scan-tool clear-code command for the meter's self-diag.
Failure Chart for "Error code"
0
Detectable itemsFuel level sensor signal circuit
Description of the failureShort circuit to ground
Displayed figure — Failure*1
Displayed figure — No failure0
1
Detectable itemsFuel level sensor signal circuit
Description of the failureOpen circuit
Displayed figure — Failure*1
Displayed figure — No failure0
2
Detectable itemsVehicle speed sensor signal circuit
Description of the failureShort circuit
Displayed figure — Failure*1
Displayed figure — No failure0
3
Detectable itemsCPU
Description of the failureEEPROM failure
Displayed figure — Failure*1
Displayed figure — No failure0
4
Detectable itemsVehicle speed sensor signal
Description of the failureFrequency of abnormal input signal
Displayed figure — Failure*1
Displayed figure — No failure0
5
Detectable itemsEngine speed signal from ECM
Description of the failureFrequency of abnormal input signal
Displayed figure — Failure*1
Displayed figure — No failure0
6
Detectable itemsEngine coolant temperature signal circuit
Description of the failureOpen circuit
Displayed figure — Failure*1
Displayed figure — No failure0
7
Detectable itemsEngine coolant temperature signal circuit
Description of the failureShort circuit
Displayed figure — Failure*1
Displayed figure — No failure0
NOTE
*: The error code can be reset by disconnecting battery cable or finish self-diagnosis mode via time out (20s).