BATTERY — Battery Test and Charging Chart (Cont'd) — Quick Charge / Service Data
EL-22flowchartK11 stock battery spec: 46B24R(L), 12V 36AH — quick-charge current 15 A.
Battery Test and Charging Chart (Cont'd)
C: Quick Charge
28B19R(L) / 34B19R(L)
Quick-charge current (A)10
46B24R(L) / 55B24R(L) / 50D23R(L)
Quick-charge current (A)15
55D23R(L) / 65D26R(L) / 80D26R(L)
Quick-charge current (A)20
75D31R(L) / 95D31R(L) / 115D31R(L) / 95E41R(L)
Quick-charge current (A)30
130E41R(L)
Quick-charge current (A)40
1.100 - 1.130
Quick-charge duration2.5 hours
1.130 - 1.160
Quick-charge duration2.0 hours
1.160 - 1.190
Quick-charge duration1.5 hours
1.190 - 1.220
Quick-charge duration1.0 hours
Above 1.220
Quick-charge duration0.75 hours (45 min.)
CAUTION
a. Do not use standard charge method on a battery whose specific gravity is less than 1.100.
b. Set charging current to value specified in Fig. 6. If charger is not capable of producing specified current value, set its charging current as close to that value as possible.
c. Keep battery away from open flame while it is being charged.
d. When connecting charger, connect leads first, then turn on charger. Do not turn on charger first, as this may cause a spark.
e. Be careful of a rise in battery temperature because a large current flow is required during quick-charge operation. If battery temperature rises above 60°C (140°F), stop charging. Never charge battery when its temperature is above 60°C (140°F).
f. Do not exceed the charging time specified in Fig. 6, because charging battery over the charging time can cause deterioration of the battery.
Service Data and Specifications (S.D.S.)
Battery type
Value46B24R (L)
Capacity (V-AH)
Value12 V - 36 AH
CAUTION
a. If it becomes necessary to start the engine with a booster battery and jumper cables, use a 12-volt booster battery.
b. After connecting battery cables, ensure that they are tightly clamped to battery terminals for good contact.