Nissan Micra K11 silhouetteK11

Battery - Battery Test and Charging Chart (Cont'd) - A: Slow Charge

EL-20flowchart

Battery Test and Charging Chart (Cont'd) - A: SLOW CHARGE

A: Slow charge

1
Determine initial charging current from specific gravity referring to Fig. 2.
2
Charge battery. Check charging voltage 30 minutes after starting the battery charge.
Below 12 volts or above 15 volts
3
12 to 15 volts
O.K.
4
Continue to charge for 12 hours.
5
CHECKING SPECIFIC GRAVITY - Refer to 'Specific Gravity Check'.
6
Conduct additional charge as per Fig 3, if necessary.
Go to 'CAPACITY TEST'.

Fig. 2 - Initial Charging Current Setting (Slow charge)

Below 1.100
28B19R(L) / 34B19R(L)4.0 (A)
46B24R(L) / 55B24R(L)5.0 (A)
50D23R(L) / 55D23R(L)7.0 (A)
65D26R(L) / 80D26R(L)8.0 (A)
75D31R(L)9.0 (A)
95D31R(L) / 115D31R(L) / 95E41R(L)10.0 (A)
130E41R(L)14.0 (A)

Fig. 3 - Additional Charge (Slow charge)

Below 1.150
ActionCharge for 5 hours at initial charging current setting.
1.150 - 1.200
ActionCharge for 4 hours at initial charging current setting.
1.200 - 1.240
ActionCharge for 2 hours at initial charging current setting.
Above 1.240
ActionGo to 'CAPACITY TEST'.

See also

EL - Specific Gravity Check · EL - CAPACITY TEST

Search Manual

Search pages, specs, and procedures