ELECTRICAL LOAD SIGNAL - CONSULT-II Reference Value in Data Monitor Mode / ECM Terminals and Reference Value
EF & EC-7245prose procedureCONSULT-II Reference Value in Data Monitor Mode
Specification data are reference values.
LOAD SIGNAL (Load switch)
CONDITIONIgnition switch: ON; Rear window defogger is operating and/or lighting switch is on.
SPECIFICATIONON
LOAD SIGNAL (Load switch)
CONDITIONIgnition switch: ON; Rear window defogger is not operating and lighting switch is not on.
SPECIFICATIONOFF
ECM Terminals and Reference Value
Specification data are reference values and are measured between each terminal and ground.
65
WIRE COLORF/L
ITEMElectric load signal (Load switch)
CONDITION[Engine is running] Rear window defogger and/or lighting switch is operating and/or lighting switch is on
DATA (DC Voltage)BATTERY VOLTAGE (11 - 14V)
65
WIRE COLORF/L
ITEMElectric load signal (Load switch)
CONDITION[Engine is running] Rear window defogger and/or lighting switch is not operating and lighting switch is not on
DATA (DC Voltage)Approximately 0V