IGNITION SIGNAL - Diagnostic Procedure (Cont'd) / Component Inspection
EF & EC-7232flowchartDiagnostic Procedure (Cont'd)
CHECK INTERMITTENT INCIDENT
Component Inspection
IGNITION COIL
- 1Disconnect ignition coil harness connector.
- 2Check ignition coil for resistance as show in the figure.
3 - 2
Resistance Ω [at 25°C (77°F)]∞
1 - 3
Resistance Ω [at 25°C (77°F)]Except 0
1 - 2
Resistance Ω [at 25°C (77°F)]∞
If NG, replace ignition coil assembly.