Trouble Diagnoses - Self-diagnosis - Mode II (Exhaust gas sensor monitor)
EF & EC-42prose procedureSelf-diagnosis - Mode II (Exhaust gas sensor monitor)
DESCRIPTION
NOTE
In this mode, the RED L.E.D. displays the condition of the fuel mixture (lean or rich) which is monitored by the exhaust gas sensor.
ON
Fuel mixture condition in the exhaust gasLean
Air fuel ratio feedback control conditionClosed loop control
OFF
Fuel mixture condition in the exhaust gasRich
Air fuel ratio feedback control conditionClosed loop control
*Remains ON or OFF
Fuel mixture condition in the exhaust gasAny condition
Air fuel ratio feedback control conditionOpen loop control
NOTE
*: Maintains conditions just before switching to open loop.
HOW TO CHECK EXHAUST GAS SENSOR
- 1Set Mode II. (Refer to "HOW TO SWITCH MODES".)
- 2Start engine and warm it up until engine coolant temperature indicator points to the middle of the gauge.
- 3Run engine at about 2,000 rpm for about 2 minutes under no-load conditions.
- 4Make sure RED L.E.D. goes ON and OFF more than 5 times every 10 seconds; measured at 2,000 rpm under no-load.