FUEL PUMP - Diagnostic Procedure (Cont'd) / Component Inspection
EF & EC-7240flowchartDiagnostic Procedure (Cont'd)
CHECK INTERMITTENT INCIDENT
Component Inspection
FUEL PUMP RELAY
Check continuity between terminals 3 and 5.
12V direct current supply between terminals 1 and 2
ContinuityYes
No current supply
ContinuityNo
If NG, replace relay.
FUEL PUMP
- 1Disconnect fuel pump harness connector.