DTC P0710, P0711 CVT FLUID TEMPERATURE SENSOR CIRCUIT - Diagnostic Procedure
AT-7060flowchartDiagnostic Procedure
1. CHECK CVT FLUID TEMPERATURE SENSOR WITH TERMINAL CORD ASSEMBLY
- 1Turn ignition switch to "OFF" position.
- 2Disconnect terminal cord assembly connector in engine compartment.
- 3Check resistance between terminals 43 and 28 when CVT is cold. Resistance: Cold [20 deg C (68 deg F)] Approximately 2.6 - 2.8 kOhm.
NAT331 - 4Reinstall any part removed.
1
OK or NG
OK (Without CONSULT-II)
GO TO 3.
NG
Replace CVT assembly.
OK (With CONSULT-II)
2
GO TO 2.
2. CHECK INPUT SIGNAL OF CVT FLUID TEMPERATURE SENSOR (With CONSULT-II)
- 1With CONSULT-II: Start engine.
- 2Select "ECU INPUT SIGNALS" in "DATA MONITOR" mode for "CVT" with CONSULT-II.
- 3Read out the value of "FLUID TEMP SE". Voltage: Cold [20 deg C (68 deg F)] -> Hot [80 deg C (176 deg F)]: Approximately 2.4V -> 0.8V.
1
OK or NG
NG
Check the following item: Harness for short to ground or short to power or open between TCM, ECM and terminal cord assembly (Main harness); Ground circuit for ECM (Refer to EC section "TROUBLE DIAGNOSIS FOR POWER SUPPLY")
Check the following item: Harness for short to ground or short to power or open between TCM, ECM and terminal cord assembly (Main harness); Ground circuit for ECM (Refer to EC section "TROUBLE DIAGNOSIS FOR POWER SUPPLY")
OK
2
GO TO 4.