TROUBLE DIAGNOSIS FOR POWER SUPPLY - Wiring Diagram — CVT — MAIN (Cont'd) - TCM TERMINALS AND REFERENCE VALUE
AT-7049spec tableUnverifiedRow for terminal 25 (Ground) prints 'Battery voltage' as judgement standard which is anomalous for a ground; preserved verbatim per never-guess rule.
Wiring Diagram — CVT — MAIN (Cont'd)
TCM TERMINALS AND REFERENCE VALUE
NOTE
Remarks: Specification data are reference values.
TCM Terminals and Reference Value — Power supply
9
Wire colorY/G
ItemPower source
ConditionWhen turning ignition switch to "ON".
Judgement standard (Approx.)Battery voltage
9
Wire colorY/G
ItemPower source
ConditionWhen turning ignition switch to "OFF".
Judgement standard (Approx.)0V
18
Wire colorY/G
ItemPower source
ConditionWhen turning ignition switch to "ON".
Judgement standard (Approx.)Battery voltage
18
Wire colorY/G
ItemPower source
ConditionWhen turning ignition switch to "OFF".
Judgement standard (Approx.)0V
24
Wire colorR/B
ItemPower source (Memory back-up)
Condition—
Judgement standard (Approx.)Battery voltage
25
Wire colorB
ItemGround
ConditionWhen turning ignition switch to "ON". When turning ignition switch to "OFF".
Judgement standard (Approx.)Battery voltage
26
Wire colorB/R
ItemLine pressure sensor (Power source)
ConditionWhen turning ignition switch to "OFF".
Judgement standard (Approx.)0V
26
Wire colorB/R
ItemLine pressure sensor (Power source)
ConditionWhen turning ignition switch to "ON".
Judgement standard (Approx.)5V
34
Wire colorB
ItemGround
Condition—
Judgement standard (Approx.)—
NOTE
Document ID: NKAT0031S01