TROUBLE DIAGNOSES — Supplemental Restraint System (SRS) — Trouble Diagnoses without CONSULT-II — DIAGNOSTIC PROCEDURE 6
BF-7046prose procedureTrouble Diagnoses without CONSULT-II
DIAGNOSTIC PROCEDURE 6
Inspecting SRS malfunction parts by using "AIR BAG" warning lamp — Diagnosis mode
NOTE
SRS will not enter Diagnosis mode if no malfunction is detected in User mode.
Inspect SRS malfunction parts using AIR BAG warning lamp (Diagnosis mode)
- 1Turn ignition switch "ON".
- 2After "AIR BAG" warning lamp lights for 7 seconds, turn ignition switch "OFF" within 1 second.
- 3Wait more than 3 seconds.
- 4Repeat steps 1 to 3 three times.
- 5Turn ignition switch "ON".SRS is now in Diagnosis mode.
- 6"AIR BAG" warning lamp operates in Diagnosis mode as follows:
NOTE
If SRS does not enter Diagnosis mode even though malfunction is detected in User mode, check the battery voltage.
If the battery voltage is less than 9V, charge the battery. Then go to DIAGNOSTIC PROCEDURE 7, page BF-7051.
If the battery voltage is OK, replace the diagnosis sensor unit.