DOOR LOCK AND POWER WINDOWS — TROUBLE DIAGNOSIS — Diagnostic Procedure 3 (Cont'd)
BF-20flowchartTest E's table records voltage column as 'Yes' (i.e. battery voltage present when the switch is operated in that direction) rather than a numeric value, as printed.
Diagnostic Procedure 3 (Cont'd)
Diagnostic Procedure 3 — continuation from BF-19
Rendering diagram…
Test E — passenger-side motor-circuit voltage at switch connector
22
Terminal (−)GND
Switch operationUp
VoltageYes
23
Terminal (−)GND
Switch operationDown
VoltageYes
Test F — motor connector D12 supply voltage
1
Terminal (−)GND
Switch operationUp
VoltageApprox. 12V
2
Terminal (−)GND
Switch operationDown
VoltageApprox. 12V