TROUBLE DIAGNOSES FOR SYMPTOMS — Diagnostic Procedure 12 (ABS Warning lamp stays on when ignition switch is turned ON)
BR-7047flowchartTerminal *1 differs: pin 10 on MT models, pin 21 on CVT models.
Diagnostic Procedure 12 (ABS Warning lamp stays on when ignition switch is turned ON)
Diagnostic Procedure 12 — ABS Warning lamp stays on
1
A — CHECK WARNING LAMP.
1. Disconnect ABS actuator and electric unit connector.
2. Connect suitable wire between ABS actuator and electric unit connector (E96) (body side) terminal 10, 21 and ground.
Warning lamp should not activate.
No
Repair combination meter.
Repair combination meter.
Check the following
• Harness connector (E96)
• Harness for open or short between ABS actuator and electric unit and fusible link
If NG, repair harness ro connector
OK
2
CHECK HARNESS CONNECTOR.
Check ABS actuator and electric unit pin terminals for damage or the connection of ABS actuator and electric unit harness connector.
Reconnect ABS actuator and electric unit harness connector. Then retest.
OK
Inspection end.
NG
3
B — CHECK ABS MOTOR GROUND.
1. Turn ignition switch OFF.
2. Disconnect ABS actuator and electric unit connector.
3. Check continuity between ABS actuator and electric unit connector (E96) (body side) terminal 16 and ground.
Continuity should exist.
NG
Check the following
Check the following
• Harness connector (E96)
• Harness for open or short between ABS actuator and electric unit and fusible link
If NG, repair harness ro connector
OK
4
REPLACE.
Replace ABS actuator and electric unit.