TROUBLE DIAGNOSES
BR-7020flowchartSelf-diagnosis
FUNCTION
Self-diagnosis procedure
Drive vehicle over 30 km/h (19 mph) for at least one minute.
Turn ignition switch to the "LOCK" position.
Turn ignition switch to the "LOCK" position.
A
A
Ground terminal "L" of "DATA LINK CONNECTOR for CONSULT-II" with a suitable harness.
Ground terminal "L" of "DATA LINK CONNECTOR for CONSULT-II" with a suitable harness.
Turn ignition switch to "ON" position while grounding terminal "L". Do not depress brake pedal and do not start engine.
Turn ignition switch to "ON" position while grounding terminal "L". Do not depress brake pedal and do not start engine.
B
B
After 3.0 seconds, the ABS warning lamp starts flashing to indicate the malfunction code No. (See NOTE.)
After 3.0 seconds, the ABS warning lamp starts flashing to indicate the malfunction code No. (See NOTE.)
Verify the location of the malfunction with the malfunction code chart. Refer to BR-7033. Then make the necessary repairs following the diagnostic procedures.
Verify the location of the malfunction with the malfunction code chart. Refer to BR-7033. Then make the necessary repairs following the diagnostic procedures.
After the malfunctions are repaired, erase the malfunction codes stored in the control unit. Refer to BR-7021.
After the malfunctions are repaired, erase the malfunction codes stored in the control unit. Refer to BR-7021.
Rerun the self-diagnostic results mode to verify that the malfunction codes have been erased.
Rerun the self-diagnostic results mode to verify that the malfunction codes have been erased.
C
C
Disconnect the check terminal from the ground. The self-diagnostic results mode is now complete.