TROUBLE DIAGNOSES
BR-7023flowchartCONSULT-II Inspection Procedure
SELF-DIAGNOSIS PROCEDURE
CONSULT-II self-diagnosis procedure
A
1) Turn ignition switch to the "OFF" position. 2) Connect CONSULT-II to Data Link Connector.
1) Turn ignition switch to the "OFF" position. 2) Connect CONSULT-II to Data Link Connector.
1) Start engine. 2) Drive vehicle over 30 km/h (19 mph) for at least one minute.
1) Start engine. 2) Drive vehicle over 30 km/h (19 mph) for at least one minute.
B
C
D
1) Stop vehicle with engine running and touch "START" on CONSULT-II screen. 2) Touch "ABS". 3) Touch "SELF-DIAG RESULTS". The screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
1) Stop vehicle with engine running and touch "START" on CONSULT-II screen. 2) Touch "ABS". 3) Touch "SELF-DIAG RESULTS". The screen shows the detected malfunction and how many times the ignition switch has been turned since the malfunction.
MALFUNCTION REPAIR Make the necessary repairs following the diagnostic procedures.
MALFUNCTION REPAIR Make the necessary repairs following the diagnostic procedures.
After repairing the malfunctions, erase the self-diagnostic results stored in the control unit by touching "ERASE".
After repairing the malfunctions, erase the self-diagnostic results stored in the control unit by touching "ERASE".
Check ABS warning lamp for deactivation after driving vehicle over 30 km/h (19 mph) for at least one minute.
Check ABS warning lamp for deactivation after driving vehicle over 30 km/h (19 mph) for at least one minute.
End