Nissan Micra K11 silhouetteK11

SERVICE PROCEDURES — Refrigerant Lines

HA-25parts diagram

Refrigerant Lines

Unknown block type: list
Parts Diagram
Diagram image not available
#Part NameNotes
AConnection at cooling unit (Low-pressure suction)Tightening torque 25-34 N·m (2.5-3.5 kg-m, 18-25 ft-lb); Wrench size 27; O-ring size 16 / 24
BConnection at cooling unit / under-bulkhead jointTightening torque 10-20 N·m (1.0-2.0 kg-m, 7-14 ft-lb); Wrench size 17 / 19; O-ring size 8
CConnection at dual-pressure switch / liquid tankTightening torque 3-4 N·m (0.3-0.4 kg-m, 2.2-2.9 ft-lb); Wrench size 10; O-ring size 8
DCompressor and condenser line connectionsTightening torque 8-11 N·m (0.8-1.1 kg-m, 5.8-8.0 ft-lb); Wrench size 12; O-ring size 12
EService-valve cap / accessoryTightening torque 10-12 N·m (1.0-1.2 kg-m, 7-9 ft-lb)