Nissan Micra K11 silhouetteK11

DISCHARGING, EVACUATING, CHARGING AND CHECKING — Work Procedure

HA-14flowchart

Work Procedure

Discharging / Evacuating / Charging / Checking work procedure

1
Install the service tools.
2
Discharge refrigerant into recycling equipment.
if tank becomes full
Recycle refrigerant if tank becomes full.
Recycle refrigerant if tank becomes full. Charging [approx. 200 g (7.05 oz)]. Preliminary refrigerant leak check.
3
Repair or replace parts.
4
Evacuate the unwanted air in charging hoses.
5
Evacuating (over 5 minutes).
6
Check air tightness.
not air-tight
Repair.
Repair. Evacuate the unwanted air in charging hoses. Evacuating (over 5 minutes). Check air tightness.
air-tight
7
Evacuating (over 20 minutes).
8
Charging [approx. 200 g (7.05 oz)].
9
Preliminary refrigerant leak check.
leak
same as step 6
no leak
10
Charging [specified amount — 200 g (7.05 oz)].
11
Check for refrigerant leaks.
leak
same as step 6
no leak
12
Check amount of refrigerant and operation of A/C system.
13
Recover refrigerant in charging hoses.
14
Remove service tools.

Search Manual