SERVICE DATA AND SPECIFICATIONS (S.D.S.)
LC-13spec tableOil pressure differs between CG10DE and CG13DE engines. Thermostat available in Standard (82°C) and cold-area (88°C) grades.
Engine Lubrication System
Oil pressure check
Oil Pressure — Approximate discharge pressure
650 - 750
Engine CG10DE — kPa (bar, kg/cm², psi)78.456 - 117.684 (0.785 - 1.177, 0.8 - 1.2, 11 - 17)
Engine CG13DE — kPa (bar, kg/cm², psi)78.456 - 117.684 (0.785 - 1.117, 0.8 - 1.2, 11 - 17)
2000
Engine CG10DE — kPa (bar, kg/cm², psi)294.210 - 411.894 (2.942 - 4.1189, 3 - 4.2, 43 - 60)
Engine CG13DE — kPa (bar, kg/cm², psi)294.210 - 372.666 (2.942 - 3.727, 3 - 3.8, 43 - 54)
6000
Engine CG10DE — kPa (bar, kg/cm², psi)490.350 - 568.806 (4.904 - 5.688, 5 - 5.8, 71.1 - 82.476)
Engine CG13DE — kPa (bar, kg/cm², psi)441.315 - 519.771 (4.413 - 5.198, 4.5 - 5.3, 64 - 75)
Oil pump inspection
Oil Pump Clearances
Body to outer gear clearance
Unit: mm (in)0.1114 - 0.200 (0.0045 - 0.0079)
Inner gear to outer gear tip clearance
Unit: mm (in)Below 0.18 (0.0071)
Body to inner gear clearance
Unit: mm (in)0.05 - 0.09 (0.0020 - 0.0035)
Body to outer gear clearance
Unit: mm (in)0.05 - 0.11 (0.0020 - 0.0043)
Inner gear to brazed portion of housing clearance
Unit: mm (in)0.045 - 0.11 (0.0018 - 0.0043)
Regulator valve inspection
Regulator Valve to Housing Clearance
Regulator valve to regulator housing clearance
Unit: mm (in)0.040 - 0.100 (0.0016 - 0.0039)
Engine Cooling System
Thermostat
Thermostat Valve Specifications
Valve opening temperature °C (°F)
Standard82 (179)
For cold area88 (190)
Max. valve lift mm/°C (in/°F)
Standard8/95 (0.31/203)
For cold area8/101 (0.31/214)